The table shows the information stored on the RFID tag(s) of the installed column(s). The active (currently selected) column is highlighted.
By default, only the columns up to and including Injections are shown; click at the top right of the table to show the full table, and to show the reduced table.
The following column tag information is provided:
Tag Status |
Shows the status of the column ID tag:
| |||
Location | The location of the column in the Integrated Column Compartment. | |||
Color Code |
The color representing the column currently occupying the valve position. | |||
Import |
Present only when the ChemStation is used. Click
| |||
Description |
A description of the column. | |||
Length [mm] |
The length of the column. | |||
Diameter [mm] |
The internal diameter of the column | |||
Particle Size [µm] | The particle size of the column packing material. | |||
Maximum Pressure | The maximum pressure supported by the column. | |||
Injections |
The number of injections made on the column. If this information has been retrieved from a tag that is present, you can edit this field; otherwise, the field is read-only. | |||
Product number | The product number of the column. | |||
Comment |
A user-generated comment about the column. If this information has been retrieved from a tag that is present, you can edit this field; otherwise, the field is read-only.
| |||
Maximum Temperature [°C] | The safe maximum operating temperature of the column. | |||
Maximum pH |
The maximum pH supported by the column. | |||
Void Volume [mL] | The void volume of the column. | |||
Serial Number |
The serial number of the column. | |||
Batch Number |
The batch number of the column. | |||
First Injection | The date and time of the first injection onto the column. | |||
Recent Injection | The date and time of the most recent injection onto the column. | |||
Manufacturing Date | The date of manufacture of the column. | |||
Minimum pH |
The minimum pH supported by the column. | |||
Maximum Measured Temperature | The highest temperature experienced by the column to date. |
The characters ; (semicolon),' (single quote) and " (double quote) are invalid for the Column Tag Information table. If these characters are used in any field of the table, an error is displayed and is disabled. You must delete all invalid characters before you can write the data to the tag. |
The information is provided for documentation purposes only. Be aware that the values are not used to validate your current method parameters (for example, maximum pressure settings). |
The data in the table is replaced by the values from the instrument. This applies to all tags in the system. | |
If changes are detected, the Column Tags Changed dialog box is displayed to allow you to choose what to do:
|
Clear Column Tag Information | Clears all fields in the selected row of the table.
| |||
Seal Column Tag | All fields except Comment and Void Volume will be set irrevocably to read-only. | |||
Copy |
Copies the contents of the selected row (except the Location and Color Code fields) to the clipboard. | |||
Paste |
Pastes the contents of the clipboard into the selected row (except the Location and Color Code fields). |
The changes to the column tag information are written only when you leave the Column Assignment dialog box by clicking . If you leave the Column Assignment dialog box by clicking , all changes (including Seal Column Tag) are discarded.