Shows the status of the parking decks. The display is updated as cuts are parked or analyzed:
When Bypass is displayed, the solvent is flowing through the capillary, but the deck is not being used for parking, analysis or flushing. When there are no parking decks, the labels are Loop A and Loop B. | |
| When the solvent level falls below the specified volume, the yellow warning is shown; when the bottle is empty, the red error is shown. Clicking on the solvent bottle displays the Bottle Fillings dialog box. The tooltip for the bottle shows the solvent name. |
Indicates the presence of a solvent selection valve. Use the context menu to switch the valve. | |
| The pressure setpoints. The red line shows the current maximum pressure limit; the gray area shows the current pressure (also shown as text). |
The following pump actuals are displayed:
Flow |
The current solvent flow rate (in mL/min). |
Pressure | The current pump pressure (in bar or psi). |
Pressure Limit | The current maximum pressure limit. |
Composition A, B | The percentage contribution of each of the solvent channels to the current solvent composition. When a solvent selection valve is fitted, the channels are shown in the graphic. |
Prepare Pump |
Displays the current pump preparation operation and the run time for Prime. |
Diverter Valve Position | Shows the current position of the diverter valve. This item is present only when a diverter valve is configured. |
ASM Valve Position | Shows the current position of the ASM valve. |
Deck A/B Valve Position | Shows the current position of the parking deck valves. These items are present only when parking deck valves are configured. |
Tuning <Channel> |
Indicates the tuning efforts of 1290 Infinity pumps. For pumps operating as expected, the signal should stay in a range of -1 to +1 within the full scale of -2 to +2. |
The context menu contains the following commands:
| Displays the pump's Control dialog box. |
| Displays the pump's Method Setup dialog box. |
|
|
|
Displays a list of devices to identify. The LED on the front of the selected module blinks for a few seconds. |
|
Toggles the status of the pump, on or off. |
| Switches the solvent selection valve to the alternative position. These menu items are present only when a solvent selection valve is configured. |
| Displays the Bottle Fillings dialog box. |
| Displays the Prepare Pump dialog box. (G7120A and G4220A) |
| Allows you to ensure that all air bubbles in the seal wash lines are removed (for example, after the seal wash solvent bottle has been refilled). (G7120A only) |
| Select the valve to switch from the submenu
|
|
Select what to modify from the submenu:
|