2D-LC Dashboard Panel

Module Graphic

Actuals

The following pump actuals are displayed:

Flow

The current solvent flow rate (in mL/min).

Pressure

The current pump pressure (in bar or psi).

Pressure Limit

The current maximum pressure limit.

Composition A, B

The percentage contribution of each of the solvent channels to the current solvent composition. When a solvent selection valve is fitted, the channels are shown in the graphic.

Prepare Pump

Displays the current pump preparation operation and the run time for Prime.

Diverter Valve Position

Shows the current position of the diverter valve. This item is present only when a diverter valve is configured.

ASM Valve Position

Shows the current position of the ASM valve.

Deck A/B Valve Position

Shows the current position of the parking deck valves. These items are present only when parking deck valves are configured.

Tuning <Channel>

Indicates the tuning efforts of 1290 Infinity pumps. For pumps operating as expected, the signal should stay in a range of -1 to +1 within the full scale of -2 to +2.

Context Menu

The context menu contains the following commands:

Control

Displays the pump's Control dialog box.

Method

Displays the pump's Method Setup dialog box.

Error Method

  • Set Error Method

    Sets the error method to the method that is currently available in the hardware. The error methods are loaded automatically on all modules if an error occurs.

  • Clear Error Method

    Removes the currently loaded error method.

Identify

Displays a list of devices to identify. The LED on the front of the selected module blinks for a few seconds.

Switch On/Off

Toggles the status of the pump, on or off.

Switch Solvent Selection Valve A/B

Switches the solvent selection valve to the alternative position. These menu items are present only when a solvent selection valve is configured.

Bottle Fillings

Displays the Bottle Fillings dialog box.

Prepare Pump

Displays the Prepare Pump dialog box. (G7120A and G4220A)

Seal Wash Prime

Allows you to ensure that all air bubbles in the seal wash lines are removed (for example, after the seal wash solvent bottle has been refilled). (G7120A only)

Switch Valve

Select the valve to switch from the submenu

  • Switch Diverter Valve

    Toggles the diverter valve between Position 1 and Position 2. This item is shown only when a diverter valve is configured.

  • Switch 2D-LC Valve

    Toggles the 2D-LC valve between Position 1 and Position 2. This item is shown only when a 2D-LC valve is configured.

  • Switch ASM Valve

    Displays the Switch ASM valve position dialog box, which allows you to switch the ASM valve to a different position.

  • Switch Deck A/B Valve

    Displays the Switch Deck A/B valve position dialog box, which allows you to switch the selected parking deck valve to a different position.

Modify

Select what to modify from the submenu:

  • Capillaries

    Displays the Modify Capillaries dialog box, which allows you to change the capillary configuration.

  • Transfer Volumes

    Displays the Modify Transfer Volumes dialog box, which allows you to change the transfer volumes.