The items in the multicolumn thermostat graphic have the following meaning and function:
| Shows the status of the column thermostat, off |
| or on. The current temperatures of the left and right column thermostats are displayed below the graphic. If temperature control is enabled in the current method, the current temperature setpoints are displayed in square brackets. |
| Shows that a Thermal Equilibration Device is installed. |
| Shows the current position of the valve. The graphic shows the actual installed valve.
|
| The color of the column graphic denotes the currently selected column. The column graphic tooltip shows the column tag details (if available). The column description (if available) is displayed below the column graphic. |
The following multicolumn thermostat actuals are displayed:
Temp. Left |
The current actual temperature (left) and setpoint temperature (right) of the left column heat exchanger. |
Temp. Right |
The current actual temperature (left) and setpoint temperature (right) of the right column heat exchanger. |
Valve Position |
The current valve position. |
The context menu contains the following commands:
Control | Displays the multicolumn thermostat's Control dialog box. | |
Method | Displays the multicolumn thermostat's Method Setup dialog box. | |
| Error Method |
|
| Identify Device | Causes the LED on the front of the module to blink for a few seconds. |
Switch Valve | Displays the multicolumn thermostat's Switch Valve Position dialog box. | |
Switch On | Switches the column compartment thermostat on. | |
Switch Off | Switches the column compartment thermostat off. | |
Column Assignment | Displays the Column Assignment dialog box. |
The column graphic tooltip shows the column tag details of the selected column (if available).
Description | A description of the column. |
Length | The length of the column in mm. |
Diameter | The internal diameter of the column in mm. |
Particle Size | The particle size of the column packing material in µm. |
Maximum Pressure | The maximum pressure supported by the column. |
Number of Injections | The number of injections that have been made on the column. |
Product Number | The product number of the column. |
Maximum Measured Temp. | The highest temperature experienced by the column to date. |
Maximum Temperature | The safe maximum operating temperature of the column. |
Minimum pH | The minimum pH supported by the column. |
Maximum pH | The maximum pH supported by the column. |
Void Volume | The void volume of the column and fittings. |
First Injection | The date and time of the first injection onto the column. |
Recent Injection | The date and time of the most recent injection onto the column. |
Manufacturing Date | The date of manufacture of the column. |
Agilent Column | Whether or not the column was supplied by Agilent Technologies. |
Serial Number | The serial number of the column. |
Batch Number | The batch number of the column. |
Tag Sealed | Whether or not all static fields except Comment and Void Volume are set irrevocably to read-only. |
Comment | A user-generated comment about the column. |